Metropolitan Building Approvals
Commercial Fit-Out Approvals Sydney
Office, retail and hospitality tenancy work, assessed in the context of the existing building, its lawful use and your proposed changes.
Request a fee proposalIllustrative architectural photography — not an MBA project. Unsplash
Your project, considered
A commercial fit-out is more than an interior layout. The existing approval, proposed business use, building classification and changes to fire safety, access or services can all influence what is required. Metropolitan Building Approvals helps owners, tenants, designers and contractors understand the certification scope for commercial fit-out approvals in Sydney.
01
Start with the premises, the use and the work
Before deciding on a pathway, distinguish the use of the premises from the building work. Replacing finishes in an existing office is different from converting a shop to a food premises, changing occupancy or altering exits. Describe both what the business will do and what the fit-out will physically change.
Offices are generally Class 5, while shops and many food or hospitality premises are Class 6. Classification depends on the actual use. A tenancy may also sit in a building with apartments, parking or other commercial uses, bringing shared building systems and mixed-use considerations into the assessment.
When engaging a commercial fit-out certifier in Sydney, provide the tenancy location, existing approval details and a clear scope. Landlord or building-manager approval is valuable, but it does not replace the planning and certification requirements that apply to the work.
02
Exempt development, CDC or DA and CC?
Some minor alterations or changes of use may be exempt development if all applicable standards and restrictions are met. Exempt does not mean that building safety, existing consent conditions or other approvals can be ignored. Do not assume that work is exempt because it is internal or inexpensive.
Eligible commercial alterations or changes of use may be assessed through a Complying Development Certificate. The proposed work, lawful existing use, site and relevant code provisions need to be considered together. Shop fit-out approvals are not automatically CDC approvals, and a tenancy in a previously approved building is not automatically eligible.
Where a Development Application is required, the consent authority determines the planning application. A Construction Certificate may then be needed for the approved building work. Change of use approvals in NSW depend on the circumstances; the planning use, building classification and construction scope are related but are not interchangeable.
CDC eligibility and assessmentConstruction Certificate documentation
03
Office and retail documentation

Office fit-out certification starts with plans that clearly distinguish existing conditions from proposed work. Show partitions, meeting rooms, work areas, exits, accessible paths and sanitary facilities. Identify the occupancy and any changes to the services, structure or fire-safety measures.
For retail or hospitality work, describe customer areas, back-of-house spaces, storage and any food preparation. Ventilation, waste, plumbing, food-business requirements or other approvals may need separate specialist input. Certification is not a substitute for every licence, council approval, utility approval or landlord requirement.
- Tenancy and site address, proposed business use, occupancy and a written work scope.
- Existing approvals and plans where available, together with owner authority.
- Existing and proposed layouts, elevations and specifications.
- Details of structural changes and affected building services.
- Relevant fire-safety, access, ventilation and other supporting evidence.
- Information about shared exits, amenities and building systems affected by the tenancy.
04
Working within an existing building
A new partition can affect an exit path, a ceiling change can affect a fire-safety system, and a different use can change the assumptions behind the existing approval. Assessment needs to consider those consequences rather than only the appearance of the finished interior.
Speak with the owner or building manager about the existing fire-safety schedule, services information and approval records. Where records are missing, identify the gap early. An inspection, further investigation or additional professional documentation may be needed; an old drawing is not proof that the current premises match it.
Fit-outs within buildings containing a Class 2 part may involve additional Design and Building Practitioners requirements, depending on the building work and applicable exclusions. The presence of apartments above a tenancy should be raised at the outset, not discovered after documentation has been prepared.
05
From assessment to occupation
Once the pathway and service scope are established, submit the coordinated plans and supporting information for assessment. Resolve information requests before relying on a certificate or commencing work that requires approval. Arrange the Principal Certifier and required inspection or notification steps where applicable.
Allow for completion evidence as well as the construction programme. Where an Occupation Certificate is required, the relevant consent, inspections and compliance documentation must be addressed before occupation or use begins. Neither a lease commencement date nor landlord handover replaces those requirements.
Tell the certifier if the layout, services or use changes during construction. Construction Certificates and Complying Development Certificates cannot retrospectively authorise building work already carried out. Discuss proposed changes and obtain any required approvals before undertaking the affected work.
Principal Certifier servicesOccupation Certificate requirements
Project questions
Frequently asked questions
Do partitions and cosmetic changes need approval?
It depends on the scope and whether every relevant exempt-development requirement is met. Internal work can still affect exits, accessibility, fire measures or structure. Provide a before-and-after layout rather than assuming that all internal changes are exempt.
Does converting a shop to a café change the pathway?
It can. The lawful existing use, proposed use, work and relevant planning standards must be checked. Food preparation, ventilation, amenities and other requirements can also need specialist assessment or separate approvals.
Is landlord approval enough?
No. The landlord’s consent and the applicable statutory approval requirements are separate. You may also need approvals or information from the building manager, council, utility providers or other responsible parties depending on the project.
What if existing approval or fire-safety documents are missing?
Ask the owner or building manager for available records and identify what is unavailable. The certifier can consider what further investigation or supporting evidence is needed. Missing records should not be replaced by assumptions about the building’s approval or compliance.
Does every fit-out need an Occupation Certificate?
No single answer applies to all fit-outs. The work, use, approval pathway and relevant statutory provisions determine whether an Occupation Certificate is required. Confirm that position before scheduling occupation or opening.
What if the tenancy is beneath apartments?
Flag the mixed-use building at the initial enquiry. Shared services, fire separation and access may need coordinated assessment, and the DBP scheme may apply to relevant work in a building containing a Class 2 part, subject to its scope and exclusions.
Related certification services
Complying Development Certificates
Eligibility and combined planning/construction assessment
Construction Certificates
Construction documentation following development consent
Principal Certifier Services
Appointment, statutory inspections and certification
Occupation Certificates
Completion documentation and applicable occupation assessment
BCA / NCC Compliance
Building-code assessment and supporting compliance advice
Other project types
Speak with MBA
Request a project-specific fee proposal
Send the tenancy address, proposed use, existing and proposed plans, and available approval details so we can consider your fit-out certification requirements.
This information is general guidance. The applicable pathway, documentation and certification requirements depend on the project, site, approvals and legislation. Obtain project-specific advice before commencing work or occupation.